113 年 國立中興大學電機工程學系碩士班丁組《計算機組織》
第 1 題15 分
For the digital arithmetic and logic designs, please select which statements (multiple choices) are correct?
(A) For an -bit adder with carry look-ahead, the maximum gates delay is .
(B) To implement an -bit ripple-carry adder, the number of required 1-bit full adders is .
(C) The required gate number for the adder with carry look-ahead is smaller than that of the ripple-carry adder.
(D) To design an unsigned multiplier, the required bits width for the output is .
(E) For a signed adder with 2's complement and no-overflow/no-underflow design, the required bits width of the adder's output is 10.
(F) For a signed adder with 2's complement, to avoid overflow and underflow, the values of inputs and the corresponding outputs must be within to .
(G) We can implement a Boolean function with a 16-to-1 multiplexer and some logic gates.
登入後即可作答並保存紀錄。
核心觀念
本題涵蓋數位邏輯與計算機組織中的多項算術與邏輯電路核心觀念:
- 加法器架構與延遲:
- 漣波進位加法器(Ripple-Carry Adder, RCA):由 個 1 位元全加器(Full Adder, FA)串接而成, 位元 RCA 需 個全加器,其關鍵路徑(Critical Path)延遲與位元數 成正比()。
- 超前進位加法器(Carry Look-ahead Adder, CLA):利用生成信號 與傳遞信號 (或 ),將所有進位訊號展開為兩層邏輯(AND-OR),藉由增加硬體閘數與面積代價換取常數級或對數級的高速進位延遲(單層 CLA 為 ,多層階層式 CLA 為 )。
- 乘法器輸出位元寬度:兩個無號整數相乘(),最大乘積為 ,所需輸出位元寬度剛好為 位元。
- 二補數(2's Complement)算術與溢位(Overflow):
- 位元二補數的表示範圍為 。
- 兩個 位元二補數相加,若輸出位元數維持 位元,當兩正數相加結果小於 0(正溢位)或兩負數相加結果大於等於 0(負溢位/下溢)時會發生溢位。若要保證相加絕不發生溢位,輸出必須擴展為 位元。
- 若輸出位元數維持為 位元,則運算元與對應相加的真實結果均必須落在 之內,才不會發生溢位/下溢。
- 多工器(Multiplexer, MUX)實現布林函數:
- 一個 的多工器具有 條選擇線(Selection Lines)。
- 根據夏農展開定理(Shannon's Expansion Theorem),任何 變數的布林函數皆可使用一個 的多工器搭配少許邏輯閘(最多僅需一個反相器 NOT 閘)來實現。
解題方法
逐一檢視各選項的數學推導、邏輯電路規格與硬體複雜度:
- 分析加法器延遲與閘數:比較 RCA 與 CLA 在延遲模型與硬體成本上的根本差異。
- 計算乘法器輸出範圍:以極值代入確認表達最大值所需的二進位位元數。
- 檢驗二補數加法器的數值範圍與溢位條件:由定義推導 與 加法運算的邊界值。
- 多工器函數實現:比對 5 變數函數與 16-to-1(即 )多工器的控制線與資料輸入線關係。
選項分析
-
(A) 錯誤:
位元超前進位加法器(CLA)的設計初衷正是消除進位漣波傳遞所產生的 線性延遲。
在傳統單層 CLA 中,所有進位信號 均由最初的 與各級的 經由兩層邏輯同時生成,其延遲為常數 ,與 無關;若考慮邏輯閘扇入數(Fan-in)限制而採用多層次(階層式)CLA,其延遲亦僅為 。
選項中給出的「」為漣波進位加法器(Ripple-Carry Adder, RCA)的循序傳遞延遲特性,並非 CLA 的最大閘延遲。 -
(B) 錯誤:
要實作一個 位元的漣波進位加法器,每一位元都需要一個 1 位元全加器(1-bit Full Adder),因此共需要 個全加器。
本題要求實作的是 位元的漣波進位加法器,所需 1 位元全加器的數量應為 個,而非 個。 -
(C) 錯誤:
漣波進位加法器(RCA)架構單純,每個 1 位元全加器僅需約 5 個基礎邏輯閘,整體閘數約為 ,具有最低的硬體成本。
超前進位加法器(CLA)為了並行計算進位信號,必須額外建立超前進位生成邏輯(Look-ahead Carry Generator),隨著位元數增加,內部 AND 與 OR 閘的數量大幅膨脹。因此,CLA 所需的邏輯閘總數遠大於 RCA,此為典型的「以硬體面積換取運算速度」(Trade area/cost for speed)。 -
(D) 錯誤:
設兩無號整數分別為 ( 位元)與 ( 位元):
兩數相乘的最大可能數值為:
因為最大乘積嚴格小於 ,所以表示該乘積所需的最小位元寬度恰為 位元,而非 位元。 -
(E) 錯誤:
10 位元二補數的表示範圍為 。
當兩個 10 位元二補數相加時,最小總和與最大總和分別為:
加法結果的數值範圍落在 。
第 2 題5 分
For the MIPS assembly languages, please select (single choice) which one is used for "data transfer"?
(A) addiu s2, 100
(B) slt s2, 10
(C) sb s2)
(D) slt s2, $s3
登入後即可作答並保存紀錄。
核心觀念
在 MIPS 指令集架構(ISA)中,指令依其執行的運算與功能主要劃分為以下幾大類別:
- 算術運算指令(Arithmetic Instructions):如
add、sub、addi、addiu等,用於在暫存器之間進行加、減等算術運算。 - 邏輯運算指令(Logical Instructions):如
and、or、sll、srl等,用於位元層級的邏輯運算或位移操作。 - 資料傳輸指令(Data Transfer Instructions):又稱為記憶體存取指令。由於 MIPS 採用「載入/儲存架構(Load-Store Architecture)」,所有算術與邏輯運算的操作數都必須位於暫存器內,若暫存器與主記憶體(Main Memory)之間需要互相傳遞資料,必須透過專屬的資料傳輸指令。常見指令包括:
- 載入類(Load):如
lw(Load Word)、lh(Load Halfword)、lhu、lb(Load Byte)、lbu等,將記憶體的內容複製到暫存器中。 - 儲存類(Store):如
sw(Store Word)、sh(Store Halfword)、sb(Store Byte)等,將暫存器的數值寫入主記憶體中。
- 載入類(Load):如
- 條件分支與跳躍指令(Branch and Jump Instructions):如
beq、bne、slt(比較)、j、jal、jr等,用於控制程式流程(Control Flow)。
本題旨在測驗考生能否正確辨析 MIPS 各種指令所屬的功能類別。
解題方法
判定一條 MIPS 指令是否為「資料傳輸(Data Transfer)」指令,關鍵在於觀察其操作是否牽涉暫存器(Register)與主記憶體(Memory)之間的資料搬移:
- 形式通常為
op rt, offset(rs),利用基底暫存器rs加上符號延伸後的立即值位移量offset計算出有效記憶體位址(Effective Address),再進行資料的讀取(Load)或寫入(Store)。 - 檢視各選項中指令的助記符(Mnemonic):尋找屬於 Load 或 Store 系列的指令。
選項分析
-
(A)
addiu $s1, $s2, 100:錯誤。- 此指令為 Add Immediate Unsigned,屬於 I-type 格式的算術運算指令(Arithmetic Instruction)。
- 其語意為將暫存器
$s2的值與立即值 (符號延伸至 32 位元)相加,但不觸發溢位例外(Overflow Exception),結果存入暫存器$s1$。此操作完全在 CPU 內部與暫存器間完成,不涉及記憶體資料傳輸。
-
(B)
slt $s1, $s2, 10:錯誤。- 此指令意圖進行數值比較(若以組合語言標準語法而言,搭配立即值應為
slti,部分組譯器可視為虛擬指令 pseudo-instruction),屬於條件設定/比較運算指令(Comparison / Arithmetic Instruction)。 - 其作用為比較
$s2與數值 的大小,若 \
- 此指令意圖進行數值比較(若以組合語言標準語法而言,搭配立即值應為
第 3 題10 分
For the IEEE 754 encoding of floating-point number, please select which statements (multiple choices) are correct?
(A) The underflow means a situation in which a positive exponent become too large to fit in the exponent field.
(B) For the number , the double precision binary representation of the exponent field is "01111111111".
(C) IEEE 754 uses a bias 127 for single precision.
(D) For the number , the "Fraction" part is 0.25.
登入後即可作答並保存紀錄。
核心觀念
本題考查 IEEE 754 浮點數表示法(Floating-Point Representation) 之基礎規格、欄位定義與數值轉換。
IEEE 754 浮點數標準數值表示式為:
- 欄位配置與偏移量(Bias):
- 單倍精確度(Single Precision, 32-bit):符號位元 為 1 位元,指數欄位 為 8 位元,尾數欄位(Fraction / Significand)為 23 位元。偏移量 。
- 雙倍精確度(Double Precision, 64-bit):符號位元 為 1 位元,指數欄位 為 11 位元,尾數欄位為 52 位元。偏移量 。
- 溢位定義:
- Overflow(上溢/溢位):當指數過大(正數太大或負數太負),超出指數欄位所能表達的最大上限。
- Underflow(下溢):當數值的絕對值太小,接近 0 到無法以常態化浮點數(甚至非常態化數)精確表達。
- 有效數字(Significand)與小數部分(Fraction):
- 常態化表示法中具有隱含位元(Hidden Bit),即有效數為 。
- 小數部分(Fraction)指的是小數點右側的數值,大小介於 。
解題方法
針對各選項分別進行名詞定義檢驗與進位制換算:
- 數值轉 IEEE 754 步驟:
- 將十進位數值轉換為二進位科學記號表示法:。
- 計算實際存入指數欄位的偏差值(Biased Exponent):,再轉換為對應長度的二進位。
- 取出小數點右側的二進位字串作為 Fraction,並可換算為等值之十進位純小數。
選項分析
-
(A) 錯誤
- 正指數過大而無法容納於指數欄位(too large to fit in the exponent field)的情況稱為 Overflow(上溢),而非 Underflow。
- Underflow(下溢) 是指負指數的絕對值太大(即指數太小、太負),導致該數值太靠近 0,無法以標準的指數範圍表示。
-
(B) 錯誤
- 將 轉換為二進位:
- 在雙倍精確度(Double Precision)中,指數欄位為 11 位元,。
- 儲存的指數值為:
- 轉換為 11 位元二進位為 。
- 選項給定為
"01111111111",對應之數值為 (即指數為 ),故選項錯誤。
第 4 題10 分
The following C codes are compiled into the corresponding MIPS assembly codes:
C codes:
Codes 1 : f=(g-h)+ (i-j)
Codes 2 : g=h+A[4]
Codes 3 : if (i==j) f=g+h
Codes 4 : for (i=0; i< size; i+=1) array[i]=0
Codes 5 : temp=v[k]; v[k]=v[k+1]; v[k+1]=temp;
MIPS assembly codes:
OP1 : bne s4, ELSE; add s1, t0, s2; sub s3, s0, t1
OP3 : sll a1, 2; add a0, t0, 0(t2, 4(t2, 0(t0, 4(t0, 4(s1, t0;
OP5 : loop1: sll t0, 2; add a0, zero, 0(t0, $t0, 1
Please select the proper MIPS assembly codes for the corresponding C codes. Copy the following table (Table 1) to your answer sheet and fill in the corresponding MIPS assembly codes by using OP1, OP2, OP3, OP4, and OP5.
Table 1
| C codes | MIPS assembly codes |
|---|---|
| Codes 1 | |
| Codes 2 | |
| Codes 3 | |
| Codes 4 | |
| Codes 5 |
登入後即可作答並保存紀錄。
核心觀念
本題考查 C 語言與 MIPS 組合語言(Assembly Language)的對應編譯。題目出自經典教材 Patterson & Hennessy《Computer Organization and Design》第二章的核心範例,主要涵蓋下列計算機組織基礎運算機制:
- 算術運算(Arithmetic Operations):
- 多運算子式子需拆解為基本三運算元指令(如
add、sub),並使用暫存器(Temporary Registers$t0–$t9)暫存中間結果。
- 多運算子式子需拆解為基本三運算元指令(如
- 基底定址與記憶體載入(Base-Offset Addressing &
lw/sw):- 陣列元素記憶體位址計算:若基底位址在暫存器中,常數索引需乘上資料型別大小(在 32-bit MIPS 中,
int佔 4 個位元組,偏移量為 ),再透過lw $rt, offset($rs)取值。
- 陣列元素記憶體位址計算:若基底位址在暫存器中,常數索引需乘上資料型別大小(在 32-bit MIPS 中,
- 條件分支與控制流程(Conditional Branches):
- C 語言的
if (cond) { body }在組合語言中通常以反向條件實作(例如==轉為bne跳過主體),不成立則跳轉至ELSE標記。
- C 語言的
- 迴圈與動態位址計算(Loop & Shift-Add Addressing):
- 陣列動態索引 的位址透過邏輯左移兩位(
sll $reg, $reg, 2,即乘上 4)加上基底位址求得。
- 陣列動態索引 的位址透過邏輯左移兩位(
- 經典元素置換(Swap Operation):
- 交換陣列相鄰元素需要分別以偏移量
0與4讀入暫存器後,再交叉寫回記憶體。
- 交換陣列相鄰元素需要分別以偏移量
解題方法
將 5 組 C 語言程式碼依照其運算特徵(運算子種類、控制結構、記憶體存取模式)進行分類與對應:
- Codes 1:純算術減法與加法運算,無記憶體存取指令(無
lw/sw),對應包含兩個sub與一個add的 OP2。 - Codes 2:自陣列常數索引讀取並加至變數,對應單一
lw與add的 OP4。 - Codes 3:條件判斷式
if (i == j),對應條件分支指令bne的 OP1。 - Codes 4:
for迴圈清空陣列,對應包含標記loop1、索引左移乘 4、存入$zero、以及索引遞增addi的 OP5。 - Codes 5:經典暫存交換 與 ,對應取位相鄰兩個字組並交叉寫回記憶體的 OP3。
選項分析
1. Codes 1:f=(g-h)+ (i-j) OP2
- C 語言特徵:由兩個相減運算子與一個相加運算子組成,需要 2 次
sub與 1 次add。 - MIPS 分析:
本段指令為教科書經典範例,雖然第二行題目印刷漏校將目標暫存器印為sub $t0, $s1, $s2 # $t0 = g - h sub $t0, $s3, $s4 # 原題印製筆誤,應為 sub $t1, $s3, $s4 ($t1 = i - j) add $s0, $t0, $t1 # f = (g - h) + (i - j)$t0,但整體由兩個sub接一個add的算術結構完全鎖定 Codes 1。
2. Codes 2:g=h+A[4] OP4
- C 語言特徵:需要將陣列元素
A[4]從記憶體讀出後,與變數h相加,再存入g。 - MIPS 分析:
所有選項中僅 OP4 具備「單次lw $t0, 4($s3) # 自基底陣列載入資料至 $t0(P&H 原始 offset 應為 4*4=16,題中為常數偏移載入) add $s1, $s2, $t0 # g = h + A[4]lw讀取資料後緊接add相加」的特徵,確切對應 Codes 2。
3. Codes 3:if (i==j) f=g+h OP1
- C 語言特徵:包含等號判斷
i == j的分支結構。 - MIPS 分析:
在 MIPS 慣例中,高階語言的bne $s3, $s4, ELSE # 若 i != j,跳過 if 區塊至 ELSE add $s0, $s1, $s2 # f = g + h(條件成立時執行) j EXIT # 結束==條件會被編譯為「若不相等則跳出」的bne(Branch if Not Equal)。全題只有 OP1 具備分支指令bne,故必然對應 Codes 3。
4. Codes 4:for (i=0; i< size; i+=1) array[i]=0 OP5
- C 語言特徵:迴圈結構,需在每次疊代中動態計算
&array[i]位址並寫入常數 0,隨後將計數器 $i
第 5 題10 分
For performance measurements of a program in the different four computers as follows:
Table 2
| Computer A | Computer B | Computer C | Computer D | |
|---|---|---|---|---|
| Instructions count | ||||
| Clock rate | 3 GHz | 2 GHz | 2.5 GHz | 4 GHz |
| Cycle per instruction | 1.5 | 2 | 2 | 1.5 |
(A) Which computer performs larger MIPS rating?
(B) Which computer executes the program faster?
登入後即可作答並保存紀錄。
核心觀念
本題評量計算機效能評估(Performance Measurement)的兩個基本指標:MIPS(Million Instructions Per Second) 與 CPU 執行時間(CPU Execution Time)。
-
基本單位換算:
-
核心公式:
- MIPS(百萬每秒指令數):
- CPU 執行時間(CPU Execution Time,即執行該程式所需時間): 執行時間越短者,代表執行速度越快(Faster)。
解題方法與數值推導
將四台電腦(Computer A、B、C、D)的各項數值分別代入公式計算:
1. 計算各電腦之 MIPS Rating
使用公式 :
- Computer A:
- Computer B:
- Computer C:
- Computer D:
比較四台電腦的 MIPS 大小:
因此,Computer D 擁有最大的 MIPS rating。
2. 計算各電腦之 CPU 執行時間(CPU Time)
使用公式 :
- Computer A:
- Computer B:
- Computer C:
- Computer D:
比較四台電腦的執行時間大小:
執行時間越短代表執行越快,因此 Computer D 執行該程式最快。
選項與子題分析
第 6 題30 分
To understand the relationship between forwarding, hazard detection, and ISA design, please refer to the following sequence of instructions, and assume that it is executed on a 5-stage pipelined datapath:
add r5,r2,r1
lw r3,4(r5)
lw r2,0(r2)
or r3,r5,r3
sw r3,0(r5)
(A) (5%) If there is no forwarding or hazard detection, insert nops to ensure correct execution.
(B) (5%) Repeat (A) but now use nops only when a hazard cannot be avoided by changing or rearranging these instructions. You can assume register R7 can be used to hold temporary values in your modified code.
(C) (5%) If the processor has forwarding, but we forgot to implement the hazard detection unit, what happens when this code executes?
(D) (5%) If there is forwarding, for the first five cycles during the execution of this code, specify which signals are asserted in each cycle by hazard detection and forwarding units in Figure 1.
(E) (5%) If there is no forwarding, what new inputs and output signals do we need for the hazard detection unit in Figure 1? Using this instruction sequence as an example, explain why each signal is needed.
(F) (5%) For the new hazard detection unit from (E), specify which output signals it asserts in each of the first five cycles during the execution of this code.
🖼️【此處有附圖,請對照原卷】
Figure 1
登入後即可作答並保存紀錄。
核心觀念
本題探討經典 5 階段管線處理器(IF、ID、EX、MEM、WB)中的資料危障(Data Hazard)、轉發技術(Forwarding / Bypassing)、危障偵測單元(Hazard Detection Unit)與指令排程最佳化(Instruction Rescheduling)。
- RAW(Read After Write)危障與延遲:
- 暫存器寫入發生在 WB 階段(通常在前半週期寫入),讀取發生在 ID 階段(後半週期讀取)。
- 無轉發(No Forwarding):前一指令產生的結果必須等到 WB 階段才能被後續指令讀出。因此,相鄰指令若有相依性,中間需要插入 個 stall(nop);若相隔 1 個無關指令,仍需插入 個 stall。
- 有轉發(With Forwarding):
- ALU 到 ALU:結果在 EX 結束即可轉發給下一指令的 EX 階段,延遲為 cycle。
- Load-use Hazard:
lw的資料在 MEM 階段結束才讀出,而後續指令在 EX 階段開頭就需要該數值,兩者時間差 1 個週期,無法單靠轉發消除,必須由危障偵測單元暫停(stall)管線 1 個週期。
- 經典控制訊號(如 Figure 1 所示):
- Hazard Detection Unit:偵測 Load-use hazard:
成立時觸發 stall:輸出將PCWrite設為 、IF/IDWrite設為 、並將控制多工器輸出設為 (插入 bubble)。 - Forwarding Unit:比較
EX/MEM與MEM/WB管線暫存器中的目的暫存器(Rd或Rt)與目前位於 EX 階段指令的來源暫存器(Rs、Rt),產生ForwardA與ForwardB控制多工器:00:來自 ID/EX(無轉發)。10:來自 EX/MEM(上一指令轉發)。01:來自 MEM/WB(上上指令轉發)。
- Hazard Detection Unit:偵測 Load-use hazard:
解題方法與逐步推導
給定原始指令序列:
- :
add r5, r2, r1(寫入r5,讀取r2, r1) - :
lw r3, 4(r5)(寫入r3,讀取r5) - :
lw r2, 0(r2)(寫入r2,讀取r2) - :
or r3, r5, r3(寫入r3,讀取r5, r3) - :
sw r3, 0(r5)(讀取r3, r5)
(A) 無 Forwarding 亦無 Hazard Detection Unit 時插入 nop
在沒有任何硬體轉發與停頓支援下,寫入暫存器必須在 WB 階段完成後才能被下一指令在 ID 階段讀取。相依指令間若緊鄰,必須補 個 nop;若隔 個指令,必須補 個 nop。
- 與 : 寫入
r5, 讀取r5。緊鄰相依,需在 與 之間插入 個nop。 - 與 :無相依( 寫
r3, 讀寫r2),不需要插入nop。 - 的相依性分析:
- 需要
r5(來自 ): 距 已經超過 3 個週期,無相依問題。 - 需要
r3(來自 ): 寫入r3,其後方只有 ,中間隔了 1 個指令,因此需要在 與 之間插入 個nop。
- 需要
- 與 : 寫入
r3, 讀取r3。緊鄰相依,需在 與 之間插入 個nop。
調整後的指令序列:
add r5, r2, r1
nop
nop
lw r3, 4(r5)
lw r2, 0(r2)
nop
or r3, r5, r3
nop
nop
sw r3, 0(r5)
(B) 重新排列(Rearrange)或改寫指令,盡可能減少 nop(可用 r7)
目標是藉由指令重排與重新命名暫存器,拉開相依指令間的距離(間隔至少 2 個無相依指令即可達成 nop):
- 產生
r5,供 使用;此處可先執行與 無關的指令。 - 注意到原始程式中,(
lw r2, 0(r2))需要的來源是r2,且 也是讀取r2(但不修改r2)。 - 若在 之前先做 ,
r2的舊值會被覆蓋,導致 算錯。此時利用題目提示提供的暫存器r7:- 將原先的 改為載入至
r7:lw r7, 0(r2)。 - 此時指令間無相依性,可大幅排程調動。
- 將原先的 改為載入至
- 我們先讓
lw r7, 0(r2)第一個做,接著做add r5, r2, r1。 - 此時
lw正在載入,我們排入其他不相依的指令:lw r7, 0(r2)(載入新r2的值到r7)add r5, r2, r1(讀取舊r2與r1,計算r5)add r2, r7, $zero(或是無相依的指令充當填充)。
- 更簡潔的無
nop排列方式(完全利用獨立指令填充 2 格延遲):lw r7, 0(r2)(先取記憶體,填入r7)add r5, r2, r1(計算r5,與上一行無相依)add r2, r7, $zero或or r2, r7, $zero(將結果移回r2,距第 1 行已相隔 1 個指令,但要滿足無轉發需隔 2 個指令,因此可在第 2 行後再放一條無關指令)。
檢視原始 5 條指令的資料流:
- :
r5 = r2 + r1 - :
r3 = Mem[r5 + 4] - :
r2 = Mem[r2 + 0] - :
r3 = r5 | r3 - :
Mem[r5 + 0] = r3
我們可以使用 r7 暫存 載入的數值,避開與後續 r3 的名稱衝突,並排程如下:
add r5, r2, r1lw r2, 0(r2)(讀取舊r2,此時 剛進入 EX, 讀取暫存器,讀到正確的r2)nop(填充以滿足 需要隔 2 條指令)lw r7, 4(r5)(此時 已完成 WB,讀取正確的r5)nopnopor r3, r5, r7(等待 完成 WB)nopnopsw r3, 0(r5)
若要將 nop 降至最少,最優調度策略為:
lw r7, 0(r2)(先發出 Load)add r5, r2, r1(計算r5)add r2, r7, $zero(此時距離第 1 條僅隔 1 條,仍需 1 個 nop)
經過各種排列分析,在純 5 條指令加上重命名下,關鍵相依鏈為 (長度為 4 的依賴鏈),且每一步都需要 2 個延遲槽,總共需要 個填充槽,而程式中僅有 1 條獨立指令()可供調度。
因此最少需要插入 個 nop(相較於 (A) 的 5 個 nop,若充分調度 可省去 1 個 nop,降為 個 nop):
add r5, r2, r1
lw r2, 0(r2) # 調度原本的 I3 到此處,利用舊 r2 載入新 r2,同時充當 I1 到 I2 的延遲槽
nop # 補 1 個 nop,使 r5 寫入 WB 完成
lw r3, 4(r5)
nop
nop
or r3, r5, r3
nop
nop
sw r3, 0(r5)
此排程成功將需要的 nop 數從 5 個降至 4 個。
(C) 有 Forwarding 但沒有 Hazard Detection Unit 的後果
- 在有 Forwarding 的架構中,ALU-ALU 相依性(如 )可完全被轉發解決。
- 但是,Load-use Hazard(如 與 之間對
r3的相依性)無法單靠轉發消除:- :
lw r3, 4(r5)在 MEM 階段結尾(Clock Cycle 4 結束)才會取得記憶體資料。 - :
or r3, r5, r3若沒有被 Hazard Detection Unit 停頓,會在 Clock Cycle 4 進入 EX 階段。 - 在 Cycle 4 的 EX 階段,
or指令需要r3的值,但此時lw才剛進入 MEM 階段,尚未讀出資料。
- :
- 結果:
or指令無法取得最新載入的r3數值,將會讀到舊的、過期(stale)的r3數值,導致or運算得出錯誤結果;隨後sw將錯誤的數值寫入記憶體,引發程式執行錯誤(Silent Data Corruption)。
(D) 前 5 個週期中,Hazard Detection 與 Forwarding Unit 的控制訊號
各週期進入各階段的指令流水線狀態(正常具備 Forwarding 與 Hazard Detection):
- Cycle 1:
- IF: (
add) - 尚無有效指令在 ID、EX、MEM、WB。
- 訊號:無訊號被 assert(Hazard Detection 輸出正常控制,ForwardA/B =
00)。
- IF: (
- Cycle 2:
- IF: (
lw r3, 4(r5)) - ID: (
add r5, r2, r1) - 訊號:無危障,ForwardA/B =
00。
- IF: (
- Cycle 3:
- IF: (
lw r2, 0(r2)) - ID: (
lw r3, 4(r5)) - EX: (
add r5, r2, r1) - 訊號:
- Forwarding Unit 檢查 EX 階段指令(),因前面無指令,ForwardA = 00, ForwardB = 00。
- Hazard Detection Unit 檢查 ID 階段指令(),此時 ID/EX 內為 (
MemRead = 0),不觸發停頓(PCWrite = 1,IF/IDWrite = 1)。
- IF: (
- Cycle 4:
- IF: (
or r3, r5, r3) - ID: (
lw r2, 0(r2)) - EX: (
lw r3, 4(r5)),來源為Rs = r5 - MEM: (
add r5, r2, r1),寫入目的為r5 - 訊號:
- Forwarding Unit 偵測到 EX/MEM 的寫入暫存器與 EX 的來源暫存器相依(
EX/MEM.RegisterRd == ID/EX.RegisterRs == r5):
ForwardA = 10(將 在 EX/MEM 的計算結果直接轉發給 ALU 輸入端 A)。ForwardB = 00。 - Hazard Detection Unit:ID/EX 為 (
MemRead = 1,目的為r3),而 ID 階段為 (來源為r2),暫存器不匹配(),不觸發停頓。
- Forwarding Unit 偵測到 EX/MEM 的寫入暫存器與 EX 的來源暫存器相依(
- IF: (
- Cycle 5:
- IF: (
sw r3, 0(r5)) - ID: (
or r3, r5, r3),來源包含r3 - EX: (
lw r2, 0(r2)),來源為Rs = r2,此時 MEM/WB 為 - MEM: (
lw r3, 4(r5)),載入目的為r3 - 訊號:
- Hazard Detection Unit:ID 階段指令為 (需要
r3),但前一指令(目前在 EX/MEM?不,注意!前一指令 是lw r2,而 是lw r3)。
仔細檢視管線中指令:- ID: (
or r3, r5, r3),來源為Rs = r5, Rt = r3。 - EX: (
lw r2, 0(r2)),其ID/EX.MemRead = 1,但ID/EX.RegisterRt = r2。 - 比較: 的目的
r2與 的來源r5, r3皆不相同,因此標準的 Hazard Detection Unit 不會在 Cycle 5 觸發停頓!
- ID: (
- Forwarding Unit:
- 檢查 EX 階段指令 (來源為
r2),MEM 階段為 (寫入r3),WB 階段為 (寫入r5),皆與r2無關,故 ForwardA = 00, ForwardB = 00。
- 檢查 EX 階段指令 (來源為
- Hazard Detection Unit:ID 階段指令為 (需要
- IF: (
(E) 若沒有 Forwarding,Hazard Detection Unit 需要哪些新輸入與輸出訊號?
原因與功能需求:
若完全沒有轉發單元,所有 RAW 相依性(包括 ALU-ALU、Load-use 等)都必須透過停頓管線(插入 stall/bubble)來解決。
第 7 題10 分
Assume the miss rate of an instruction cache is 2% and the miss rate of the data cache is 4%. If a processor has a CPI of 2 without any memory stalls and the miss penalty is 100 cycles for all misses, determine how much faster a processor would run with a perfect cache that never missed. Assume the frequency of all loads and stores is 36%.
登入後即可作答並保存紀錄。
核心觀念
本題評量計算機架構中記憶體階層架構對處理器效能的影響,核心在於計算快取記憶體(Cache)未命中(Miss)所引發的停頓週期(Memory Stall Cycles),進而求出處理器在真實快取與完美快取(Perfect Cache)下的效能加速比(Speedup)。
相關定義與公式如下:
- 處理器有效 CPI(Cycles Per Instruction):
- 每道指令的記憶體停頓週期(分為指令快取與資料快取兩部分):
- 效能加速比(Speedup):
在指令數(Instruction Count, )與時脈週期(Clock Cycle Time, )不變的前提下,加速比為執行時間的反比,亦即 CPI 的比值:
解題方法
步驟一:計算指令快取的停頓週期(Instruction Stall Cycles)
每一道指令在執行前皆必須經過擷取(Instruction Fetch),故指令存取頻率為 (即每道指令存取 1 次)。
步驟二:計算資料快取的停頓週期(Data Stall Cycles)
題目給定所有 Loads 與 Stores 的出現頻率為 (即 ),且資料快取未命中率為 :
步驟三:計算總記憶體停頓週期與實際 CPI
處理器無任何記憶體停頓時的理想 CPI 為 ,因此實際 CPI 為:
第 8 題10 分
Suppose you want to achieve a speed-up of 90 times faster with 100 processors. What percentage of the original computation can be sequential?
登入後即可作答並保存紀錄。
核心觀念
本題評量平行計算架構中最著名的效能評估準則——阿姆達爾定律(Amdahl's Law)。
阿姆達爾定律指出:在固定工作量(Fixed-workload)的前提下,系統整體的加速倍率(Speedup)受限於程式中無法平行化的循序執行部分(Sequential fraction)。
其公式定義如下:
設原始程式的執行時間為 。
- :原本計算中必須「循序執行」的比例(Sequential fraction),。
- :原本計算中可完全「平行化加速」的比例(Parallel fraction)。
- :投入的處理器數量(Number of processors)。
採用 顆處理器平行執行加速部分後,新的執行時間為:
整體系統的加速比 定義為:
解題方法
本題要求利用 顆處理器達成 倍的加速比,求原本計算中最多可容忍多少百分比的循序執行部分()。
步驟一:列出已知條件與方程式
- 加速比
- 處理器數量
- 循序比例 為未知數
代入阿姆達爾定律:
步驟二:代數化簡求解
將兩邊取倒數:
等號兩邊同乘以 以消除分母:
移項化簡:
步驟三:換算為百分比(Percentage)
題目要求以「百分比(Percentage)」作答: