113 年 國立成功大學環境工程學系碩士班甲組《衛生工程》
第 1 題
Answer the following questions or explain the terms.
(1) What is a master plan? Briefly describe the content. (10%)
(2) Write the reaction equations if soda-lime chemical precipitation methods are used to remove hardness (Ca2+ and Mg2+) from water. (5%)
(3) Compare the advantages and disadvantages of disinfection using free chlorine vs. combined chlorine. (5%)
(4) Compare the advantages and disadvantages of tunneling work (as 潛盾施工法) and open cut work (明挖施工法). (5%)
(5) Describe four types of sedimentation and their characteristics. (5%)
(6) Sketch the profiles (操作曲線) of head loss and turbidity in optimal filtration operation. Please label the profiles (請標示出曲線). (5%)
🖼️【此處有附圖,請對照原卷】
登入後即可作答並保存紀錄。
第 1 題:核心觀念
本題涵蓋衛生工程規劃、石灰-蘇打軟化、消毒方式比較、管線施工、沉澱型態,以及快濾池的操作曲線。第(6)小題的圖上,橫軸是過濾時間,左縱軸是濁度,右縱軸是水頭損失,另以水平虛線標示可用水頭;圖中沒有提供數值刻度,重點是畫出曲線趨勢並標明名稱。
解題方法
各小題依工程定義、化學反應式與操作特性比較作答。第(2)小題先依硬度來源區分暫時硬度與非碳酸鹽硬度;第(5)小題依懸浮粒子的沉降時是否絮凝、是否互相干擾分類;第(6)小題則在題示座標中,分別標出濁度及水頭損失隨過濾時間的變化。
(1)何謂整體規劃?內容為何?
整體規劃(master plan)是針對一定服務區域與規劃年期,依人口、土地使用及污染或用水需求,整合評估公共衛生工程設施需求,據以安排設施規模、位置、建設順序與經費的長期計畫。
主要內容包括:
- 現況調查:盤點服務區域、既有設施能力、設備狀況及環境條件。
- 需求預測:推估規劃年期內的人口、土地使用、用水量或污水量。
- 服務範圍與設計準則:訂定服務區域、設計流量、水質目標及可靠度等標準。
- 方案研擬與比較:比較不同處理流程、設施位置及系統配置的技術、環境與經濟效益。
- 設施計畫:決定設施規模、配置、管線系統及所需土地。
- 分期建設與財務計畫:安排工程優先順序、期程、資金來源及操作維護需求。
- 環境與執行計畫:評估環境影響,並規劃後續設計、施工、管理及檢討方式。
(2)石灰-蘇打法去除水中鈣、鎂硬度
石灰提供氫氧根,使鎂形成氫氧化鎂沉澱;蘇打灰(碳酸鈉)提供碳酸根,使鈣形成碳酸鈣沉澱。
暫時硬度(碳酸氫鹽硬度):
鈣離子硬度以石灰去除:
鎂離子硬度以石灰去除,生成氫氧化鎂與碳酸鈣:
非碳酸鹽硬度:
以氯化鈣為例,加入蘇打灰使鈣形成碳酸鈣沉澱:
以硫酸鎂為例,先由石灰沉澱鎂,再由蘇打灰去除反應生成的鈣:
合併為:
式中的 表示形成沉澱。判斷藥劑時,可記住:石灰主要去除碳酸氫鹽硬度並沉澱鎂;非碳酸鹽鈣硬度及由鎂鹽反應生成的鈣,需以蘇打灰提供碳酸根去除。
(3)游離氯與化合氯消毒的優缺點
| 比較項目 | 游離氯消毒 | 化合氯消毒 |
|---|---|---|
| 主要型態 | 次氯酸及次氯酸根 | 以氯胺為主 |
| 消毒能力 | 反應快、消毒能力較強 | 反應較慢、消毒能力較弱 |
| 持續消毒 | 水中殘留較不穩定,持續性較弱 | 殘留較穩定,管網維持消毒效果較久 |
| 副產物與感官 | 較易形成三鹵甲烷等消毒副產物,較可能有氯味 | 通常較少形成三鹵甲烷,氯味較低 |
| 操作注意事項 | 消毒效果受 pH 影響;需控制副產物 | 需控制氨與氯的比例;有硝化等管網管理問題,且對部分病原體的消毒效果較弱 |
若重視快速消毒,游離氯較有利;若重視管網中較持久的消毒殘留,化合氯較有利。實際選擇須同時考量原水水質、副產物標準及管網操作。
(4)潛盾施工法與明挖施工法
| 比較項目 | 潛盾施工法 | 明挖施工法 |
|---|---|---|
| 優點 | 可在地表下施工,對交通、商家及地面設施干擾較小;適合市區、較深或長距離管線 | 工法直接、設備需求較簡單,通常較容易檢查施工品質、接管及維修;淺層工程成本較低 |
| 缺點 | 潛盾機及工作井投資高;需處理地質變化、地下水、地層沉陷與施工風險;設備進場及準備時間較長 | 需開挖路面,會影響交通及既有管線;需支撐開挖面、處理地下水,並復原路面;深開挖時安全與成本負擔增加 |
選法時主要比較埋設深度、地質、管線長度、地面交通影響、既有地下設施及總工程成本。
(5)四種沉澱型態及其特性
- 離散沉澱(Type I):粒子分散且彼此不聚集,沉降時粒徑、形狀與沉降速度大致不變。稀薄懸浮液中的砂粒沉降可作為例子。
- 絮凝沉澱(Type II):粒子在沉降過程中碰撞、聚集成較大的絮體,因此粒徑與沉降速度會隨深度及時間增加。常見於混凝後的水中懸浮物。
- 阻礙沉澱或區域沉澱(Type III):懸浮固體濃度較高,粒子間互相干擾,整群粒子以近似界面向下沉降,形成清楚的沉降界面。
- 壓縮沉澱(Type IV):沉降至底部的固體濃度很高,粒子互相接觸並形成骨架;後續沉降主要靠上層固體重量壓縮下層污泥,常見於濃縮污泥層。
辨認重點是看粒子是否絮凝,以及沉降是否由單顆粒子、整體界面或底部壓縮所主導。
(6)最佳過濾操作時濁度與水頭損失曲線
題圖的橫軸為過濾時間,左側縱軸為濁度,右側縱軸為水頭損失;水平虛線是可用水頭。操作曲線應呈現濾床逐漸堵塞時水頭損失上升,以及濾後水濁度先經初期成熟而下降、維持低值,最後可能突破上升的趨勢。
第 2 題15 分
The following data have been obtained in a BOD test that is made to determine how well a wastewater treatment plant is operating. What percentage of the BOD is being removed by this treatment plant, assuming that this particular BOD test could measure 100% of the pollutants in the wastewater? If this is a secondary treatment plant that is supposed to remove 85% of the BOD, would you say it is operating properly? (15%).
| Sample | Initial D.O. (mg/L) | Final D.O. (mg/L) | Volume of wastewater (mL) | Volume of dilution water (mL) |
|---|---|---|---|---|
| Untreated sewage | 6.0 | 2.0 | 5 | 295 |
| Treated sewage | 9.0 | 4.0 | 15 | 285 |
登入後即可作答並保存紀錄。
核心觀念
未接種且忽略稀釋水空白耗氧時,水樣的生化需氧量()等於培養前後溶氧差除以水樣體積佔比(即乘以稀釋倍數):
其中 。
解題方法
- 計算進流未處理廢水(Untreated sewage)之 :
- 計算放流已處理廢水(Treated sewage)之 :
- 計算 去除率並評估運作狀態:
第 3 題20 分
A well is producing from a confined aquifer at steady state. An observation well 100 m away from the pumping well shows a drawdown, of 5 m, while an observation well 20 m away from the pumping well shows a drawdown, of 16 m. (1) If the well produces at a rate , what is the transmissivity () of the aquifer? (2) In the case where the pumping rate is unknown, what would be the drawdown, at the pumping well of radius 0.2 m? (20%)
登入後即可作答並保存紀錄。
核心觀念
本題考查受壓地下水層穩定抽水時的泰姆公式(Thiem equation)。在均質、等向性、厚度均勻且完全貫穿的受壓含水層中,穩定抽水造成的降深為
其中:
- :距抽水井 處的降深
- :抽水量
- :含水層透水量係數
- :影響半徑
- :觀測井至抽水井的距離
使用兩口觀測井相減,可消去未知的影響半徑 :
解題方法
已知:
因此:
且:
(1)求透水量係數
由兩井降深差公式:
整理得:
因此:
(2)求抽水井井壁處降深
抽水量未知時,仍可利用兩個觀測井的降深差求出單位對數距離的降深變化:
抽水井半徑為:
由 的觀測井推算至井壁:
代入數值:
因為:
第 4 題10 分
Treatment of a water supply requires 60 mg/L of FeCl3 (molecular weight of 162 g/mole) as a coagulant. The natural alkalinity of the water is 40 mg/L as CaCO3. Based on the theoretical chemical reactions, what dosage of lime as CaO (molecular weight of 56 g/mole) is required to react with FeCl3 after the natural alkalinity is consumed? (10%)
登入後即可作答並保存紀錄。
核心觀念
氯化鐵作為混凝劑時,會水解生成氫氧化鐵沉澱並產生酸性,需由水中天然鹼度及外加石灰中和。此題須比較:
- FeCl₃ 所需的總鹼度。
- 水中天然鹼度可提供的中和量。
- 天然鹼度消耗後,剩餘需求換算為 CaO 劑量。
主要反應為:
以 CaO 表示時:
因此, 莫耳 FeCl₃ 需要 莫耳 CaO。
解題方法
先計算 FeCl₃ 的莫耳濃度:
依反應式,CaO 與 FeCl₃ 的莫耳比為:
故完全反應所需的 CaO 濃度為:
這是尚未扣除天然鹼度時的總石灰需求。
天然鹼度為 。由當量關係:
- 莫耳 CaO 的分子量為 ,可提供 當量鹼度。
- 莫耳 CaCO₃ 的分子量為 ,其當量重為 。
所以, 的 CaCO₃ 當量,等效於 CaO。天然鹼度可折合消耗的 CaO 為:
因此,天然鹼度消耗後仍需補充的石灰量為:
亦可直接以鹼度差計算。每莫耳 FeCl₃ 水解約消耗 當量鹼度,因此 FeCl₃ 的鹼度需求為:
第 5 題10 分
What is the corresponding overflow rate (express unit of m/day and rounding to integer 四捨五入到整數) that can just completely remove coagulated particles with a size of 0.00075 m and density of 1001 kg/m³? (, at 25°C, ). If the flow rate is 6,000 CMD, retention time is 3 hours, design the sedimentation tank. (10%)
登入後即可作答並保存紀錄。
核心觀念
理想沉澱池理論中,欲使粒徑 的顆粒 沉降去除,其終端沉降速度 必須大於或等於沉澱池之表面負荷率(Overflow Rate, ),故臨界最大允許表面負荷率為 。
解題方法
- 以斯托克斯定律(Stokes' Law)計算顆粒沉降速度 :
代入 、、、、:
檢核雷諾數確認層流假設成立:
(層流區適用斯托克斯定律。) - 換算為表面負荷率 ():
(實務上為確保完全去除,操作之 須小於或等於此臨界值 。) - 設計沉澱池尺寸(,停留時間 ):
- 所需表面積 :
- 所需有效體積 :
- 所需表面積 :
第 6 題10 分
The results of a chlorine demand test on a raw water at 20°C are given in the following table.
| Sample | Chlorine dosage (mg/L) | Residual chlorine (mg/L) |
|---|---|---|
| 1 | 0.20 | 0.19 |
| 2 | 0.40 | 0.37 |
| 3 | 0.60 | 0.51 |
| 4 | 0.80 | 0.50 |
| 5 | 1.00 | 0.20 |
| 6 | 1.20 | 0.40 |
| 7 | 1.40 | 0.60 |
| 8 | 1.60 | 0.80 |
(a) Sketch the breakpoint chlorination curve. (5%)
(b) What is the breakpoint chlorine dosage? Indicate the dosage on the plot. (2%)
(c) What is the chlorine demand at a chlorine dosage of 1.20 mg/L? Indicate the value on the plot. (3%)
登入後即可作答並保存紀錄。
核心觀念
- 氯需求量(Chlorine Demand):加入水中的總加氯量與反應後殘餘氯量之差,即 。
- 斷點氯化(Breakpoint Chlorination):水中含氨氮或還原性物質時,加氯初期先形成結合氯(氯胺)使餘氯上升;繼續加氯會將氯胺氧化破壞(產生氮氣逸散),導致餘氯驟降並達最低點——此最低點即為斷點(Breakpoint)。超過斷點後,新增的氯不再被消耗,自由有效氯呈 (斜率為 )線性上升,氯需求量則維持恆定。
解題方法
先計算各樣本之氯需求量如下表:
| Sample | Chlorine dosage () | Residual chlorine () | Chlorine demand () |
|---|---|---|---|
| 1 | |||
| 2 | |||
| 3 | |||
| 4 | |||
| 5 | |||
| 6 | |||
| 7 | |||
| 8 |
- (a) 繪製斷點氯化曲線:
- 橫軸( 軸)標示
Chlorine dosage (mg/L)(範圍 ),縱軸( 軸)標示Residual chlorine (mg/L)(範圍 )。 - 依序描繪 、、、、、、、 並連線:曲線先上升至 附近峰頂,隨後下降至 之谷底,之後呈斜率為 的直線上升。
- 橫軸( 軸)標示
- (b) 斷點加氯量(Breakpoint Chlorine Dosage):
- 在加氯量 處,殘餘氯量降至最低點 ;此後加氯量每增加 ,殘餘氯量亦同步增加 (),氯需求量穩定維持在 。